Object Identifier Types
Object Identifier Types
Object identifiers (OIDs) are used internally by Tacnode as primary keys for various system tables. Type oid
represents an object identifier. There are also several alias types for oid
, each named reg `something`
. Table 7.23 shows an overview.
The oid
type is currently implemented as an unsigned four-byte integer. Therefore, it is not large enough to provide database-wide uniqueness in large databases, or even in large individual tables.
The oid
type itself has few operations beyond comparison. It can be cast to integer, however, and then manipulated using the standard integer operators. (Beware of possible signed-versus-unsigned confusion if you do this.)
The OID alias types have no operations of their own except for specialized input and output routines. These routines are able to accept and display symbolic names for system objects, rather than the raw numeric value that type oid
would use. The alias types allow simplified lookup of OID values for objects. For example, to examine the pg_attribute
rows related to a table mytable
, one could write:
rather than:
While that doesn't look all that bad by itself, it's still oversimplified. A far more complicated sub-select would be needed to select the right OID if there are multiple tables named mytable
in different schemas. The regclass
input converter handles the table lookup according to the schema path setting, and so it does the “right thing” automatically. Similarly, casting a table's OID to regclass
is handy for symbolic display of a numeric OID.
Table Object Identifier Types
Name | References | Description | Value Example | Constraint |
---|---|---|---|---|
oid | any | numeric object identifier | 564182 | |
regclass | pg_class | relation name | pg_type | |
regcollation | pg_collation | collation name | "POSIX" | unsupported now |
regconfig | pg_ts_config | text search configuration | english | unsupported now |
regdictionary | pg_ts_dict | text search dictionary | simple | unsupported now |
regnamespace | pg_namespace | namespace name | pg_catalog | |
regoper | pg_operator | operator name | + | unsupported now |
regoperator | pg_operator | operator with argument types | *(integer,integer) or -(NONE,integer) | unsupported now |
regproc | pg_proc | function name | sum | |
regprocedure | pg_proc | function with argument types | sum(int4) | |
regrole | pg_authid | role name | smithee | unsupported now |
regtype | pg_type | data type name | integer |
All of the OID alias types for objects that are grouped by namespace accept schema-qualified names, and will display schema-qualified names on output if the object would not be found in the current search path without being qualified. For example, myschema.mytable
is acceptable input for regclass
(if there is such a table). That value might be output as myschema.mytable
, or just mytable
, depending on the current search path. The regproc
and regoper
alias types will only accept input names that are unique (not overloaded), so they are of limited use; for most uses regprocedure
or regoperator
are more appropriate. For regoperator
, unary operators are identified by writing NONE
for the unused operand.
The input functions for these types allow whitespace between tokens, and will fold upper-case letters to lower case, except within double quotes; this is done to make the syntax rules similar to the way object names are written in SQL. Conversely, the output functions will use double quotes if needed to make the output be a valid SQL identifier. For example, the OID of a function named Foo
(with upper case F
) taking two integer arguments could be entered as ' "Foo" ( int, integer ) '::regprocedure
. The output would look like "Foo"(integer,integer)
. Both the function name and the argument type names could be schema-qualified, too.
Many built-in Tacnode functions accept the OID of a table, or another kind of database object, and for convenience are declared as taking regclass
(or the appropriate OID alias type). This means you do not have to look up the object's OID by hand, but can just enter its name as a string literal. For example, the nextval(regclass)
function takes a sequence relation's OID, so you could call it like this:
regclass
(or the appropriate type). Since this is really just an OID, it will track the originally identified object despite later renaming, schema reassignment, etc. This “early binding” behavior is usually desirable for object references in column defaults and views. But sometimes you might want “late binding” where the object reference is resolved at run time. To get late-binding behavior, force the constant to be stored as a text
constant instead of regclass
:The to_regclass()
function and its siblings can also be used to perform run-time lookups.
Another practical example of use of regclass
is to look up the OID of a table listed in the information_schema
views, which don't supply such OIDs directly. One might for example wish to call the pg_relation_size()
function, which requires the table OID. Taking the above rules into account, the correct way to do that is
The quote_ident()
function will take care of double-quoting the identifiers where needed. The seemingly easier
is not recommended, because it will fail for tables that are outside your search path or have names that require quoting.
An additional property of most of the OID alias types is the creation of dependencies. If a constant of one of these types appears in a stored expression (such as a column default expression or view), it creates a dependency on the referenced object. For example, if a column has a default expression nextval('my_seq'::regclass)
, Tacnode understands that the default expression depends on the sequence my_seq
, so the system will not let the sequence be dropped without first removing the default expression. The alternative of nextval('my_seq'::text)
does not create a dependency. (regrole
is an exception to this property. Constants of this type are not allowed in stored expressions.)
Another identifier type used by the system is xid
, or transaction (abbreviated xact) identifier. This is the data type of the system columns xmin
and xmax
. Transaction identifiers are 32-bit quantities. In some contexts, a 64-bit variant xid8
is used. Unlike xid
values, xid8
values increase strictly monotonically and cannot be reused in the lifetime of a database cluster.
A third identifier type used by the system is cid
, or command identifier. This is the data type of the system columns cmin
and cmax
. Command identifiers are also 32-bit quantities.
A final identifier type used by the system is tid
, or tuple identifier (row identifier). This is the data type of the system column ctid
. A tuple ID is a pair (block number, tuple index within block) that identifies the physical location of the row within its table.
(The system columns are further explained inSection 4.5.)